NEW QUESTION # 35
When you arrive on a customer site, you discover that the customer network administrator has called in sick. While required power has been provided and all of the components ordered have been physically accounted for, the network will not be operational today.
Which would be the most useful tool to complete your rack & stack and initial configuration of the system? (Choose the best answer.)
- A. a CD containing the 10.86 version of SANtricity
- B. a standalone switch or hub
- C. a Serial Port cable
- D. None of the above, come back tomorrow.
Answer: A
NEW QUESTION # 36
A company has just installed a NetApp EF600 storage array with an initial drive count of 12. A disk pool is created using all 12 disks. Benchmark testing now shows that system performance is far less than expected. Metrics show a very unbalanced use of the two PcIe busses and drives.
In this scenario, which action addresses this problem?
- A. Adjust cache block sizes to 8k.
- B. Insert six drives into the first 12 slots and six drives into the last 12 slots.
- C. Build two equally sized pools during disk pool creation.
- D. Dynamically convert the volumes from RAID 10 to RAID 5.
Answer: B
NEW QUESTION # 37
When working on a customer's E-Series system to configure LDAP, you realize that you need to complete a Certificate Signing Request to receive a certificate.
In this scenario, when entering the information for the CSR, what information do you need from the controllers themselves? (Choose three.)
- A. the controller's alternate names
- B. the controller's alternate IP addresses
- C. the controller's geographical location
- D. the controller's common name
- E. the controller's serial number
Answer: A,C,D
Explanation:
* When completing a Certificate Signing Request (CSR) for an E-Series system, you will need:
* The controller's geographical location: This is typically the city or locality and the country where the controller is located.
* The controller's common name: This is usually the fully qualified domain name (FQDN) of the controller.
* The controller's alternate names: These may include additional domain names or IP addresses that the certificate should also cover.
NEW QUESTION # 38
Your AutoSupport does not automatically send reports to NetApp's ActiveIQ tool.
In this scenario, how do you access the data that would have been sent using the AutoSupport feature?
- A. Access the event log by using SANtricity System Manager
- B. Ask NetApp Support to help you to access the data by using special support tools
- C. Use SANtricity System Manager to manually collect the support data
- D. Use SANtricity Unified Manager to collect the support data remotely
Answer: C
Explanation:
* Explanation:
* When AutoSupport is not automatically sending reports to NetApp's ActiveIQ tool, you can manually collect the support data using SANtricity System Manager.
* The manual collection involves generating a support bundle that includes all necessary logs and system information.
* This data can then be reviewed locally or sent to NetApp support for analysis if needed.
NEW QUESTION # 39
A junior administrator recently made changes to an E-Series system. As a result of these changes, the management host lost the ability to manage the E-Series system through in-band management, but the host still has access to the E-Series data volumes.
In this scenario, what caused this issue?
- A. The management IPs were changed
- B. Auto Load Balancing was disabled
- C. The access volume was un-mapped
- D. The ownership of the management host's volumes changed
Answer: C
Explanation:
If the management host loses the ability to manage the E-Series system through in-band management but still has access to data volumes, the most likely cause is thatthe access volume was un-mapped. The access volume is crucial for in-band management as it provides a path for management commands.
In-band management relies on this special volume to communicate management commands between the host and the storage system. If the access volume is un-mapped, the management interface on the host will no longer be able to send these commands, even though data volumes remain accessible.
References:
* NetApp E-Series SANtricity Storage Manager Documentation
* NetApp Knowledge Base Articles
NEW QUESTION # 40
For SAN zoning of E-Series systems, what type of relationship between host ports and storage system ports is a common industry practice?
- A. two-to-two
- B. many-to-one
- C. many-to-many
- D. one-to-one
Answer: D
NEW QUESTION # 41
Identify this controller.
- A. E5600
- B. E2700
- C. E5400
- D. E5500
Answer: C
NEW QUESTION # 42
You are troubleshooting a customer issue on their E-Series system. You need information on the volume configuration of the customer's system.
In this scenario, which log would you download to get the required information?
- A. IO Path Statistics
- B. Support Data
- C. Trace Buffers
- D. Health Image
Answer: B
NEW QUESTION # 43
Click the Exhibit button.
Referring to the exhibit, which three statements are true? (Choose three.)
- A. There are two Base-T iSCSI ports available
- B. There are six SAS host ports available
- C. There are four SAS host ports available
- D. There are two FC/iSCSI host ports available
- E. There are two SAS expansion ports available
Answer: A,B,D
NEW QUESTION # 44
In the AMW, which tab provides access to Ethernet management port configuration and premium feature enablement? (Choose the best answer.)
- A. Host Mappings
- B. Setup
- C. Storage & Copy Services
- D. Hardware
- E. Configuration
Answer: B
NEW QUESTION # 45
Which feature creates a full physical clone of a volume on an E-Series or EF-Series storage system?
- A. Volume Copy
- B. Snapshot volume
- C. Snapshot image
- D. FlexClone
Answer: A
NEW QUESTION # 46
Hot spares provide what function?
- A. Spare capacity for volume groups in the event of disk failure
- B. Spare capacity for any volume on the storage system
- C. Spare capacity for disk pools in the event of disk failure
- D. Efficiency for configuring volumes to maximize capacity usage
Answer: A
NEW QUESTION # 47
In SANtricity System Manager, the Recovery Guru reports a loss of paths to an iSCSI host.
In this scenario, which tool would you use to troubleshoot this issue?
- A. ping
- B. Device Manager
- C. telnet
- D. PuTTY
Answer: A
NEW QUESTION # 48
What measurement refers to the number of read/write requests that can be handled in a 1-second time period? (Choose the best answer.)
- A. I/O alignment
- B. Read modify write
- C. Throughput
- D. IOPS
- E. Parity
Answer: D
NEW QUESTION # 49
What uses the Access Volume? (Choose the best answer.)
- A. Redundancy Check
- B. SMagent
- C. Legacy operating environments
- D. Asymmetric Logical Unit
- E. XOR parity calculations
Answer: B
NEW QUESTION # 50
You have two Linux hosts that must be connected over multiple paths to two NetApp E-Series systems. One with FC and the other with SAS.
In this scenario, which mutipathing driver should you use for each system to complete this task?
- A. Use DM-MP for FC and LVM for SAS.
- B. Use DM-MP for FC and SAS.
- C. Use DM-MP for SAS and LVM for FC.
- D. Use LVM for FC and SAS.
Answer: B
NEW QUESTION # 51
Exhibit:
Referring to the exhibit, what would you select in the search list to see all of the host selections for NetApp ESeries storage systems?
- A. SANtricity
- B. E-Series SAN Host
- C. E-Series Controller Firmware
- D. Storage OS
Answer: B
NEW QUESTION # 52
Multipath drivers provide which high-level features?
- A. They specify the rate of data transfer and reroute host requests.
- B. They check the state of known and discovered paths and monitor host connections.
- C. They present volumes as LUNs to the hosts and allow you to take them offline.
- D. They identify a failed disk and its path.
Answer: B
NEW QUESTION # 53
When you replace a component, why should you wait for the action to register in the storage manager?
- A. To ensure that the controller configuration database has a record of the change
- B. To ensure that the storage manager completes the component repair sleep cycle
- C. To ensure that the administrator has time to complete ESD procedures
- D. To ensure that the host OS completes SOD processing
Answer: A
NEW QUESTION # 54
......
Network Appliance NS0-516 exam, also known as the NetApp Implementation Engineer SAN Specialist E-Series (NCIE) exam, is designed to test the knowledge and skills of IT professionals who work with NetApp E-Series SAN solutions. NS0-516 exam focuses on verifying the candidate's ability to design, implement, and manage NetApp E-Series SAN solutions in a variety of environments.
NS0-516 Cert Guide PDF 100% Cover Real Exam Questions: https://braindump2go.examdumpsvce.com/NS0-516-valid-exam-dumps.html